click me!

True Zero Order Waveplates

  • Stable retardance over certain spectral and temperature range
  • Structure: Ultra-thin free-standing single plate or constructed with substrates
  • Wide acceptance angle and accurate retardations
  • High damage threshold 1GW/cm2 (single plate versions)
  • Two types of materials: Quartz for routine wavelengths, and MgF2 for >3000nm applications
Inquire Us  

Specifications:

Material Quartz Wavelength Range532-7000nm
Dimension Tolerance ±0.1mm Surface Quality 20 / 10 S/D
Parallelism <1 arc Sec Retardation Tolerance

λ/60-λ/200(λ<400nm),

λ/200-λ/500(400nm<λ<700nm),

λ/500-λ/600(λ>700nm)

Clear Aperture >90% Damage Threshold

>1 GW/cm^2 (Single Plate),

1-2J/cm^2 (Cemented)

15J/cm^2 (Diffusion Bonded)

Coating AR coating Mounted Diameter 25.4mm (1 inch)

Conventional wavelengths and specifications of true zero order waveplates offered by Shalom EO are listed below, besides those we also accept customized requirements where all the parameters can be tailored for you.

Type1: True Zero Order Waveplate-Single Plate

This type of zero-order waveplate is designed for high damage threshold applications (more than 1GW/cm2). However, the extremely small thickness of the plate also implies that it might be susceptible to fracture and injury during operation.

Features:

  • Wide Angle Acceptance
  • Better Temperature Bandwidth
  • Wide Wavelength Bandwidth
  • High Damage Threshold
  • AR Coated, R<0.2%
  • Single Plate

Standard Wavelengths:

λ/2:1310nm, 1480nm, 1550nm
λ/4:980nm, 1064nm,1310nm, 1480nm, 1550nm

Specifications:

True Zero Order Waveplate-Single Plate
Quarter Waveplates P/N # Half Waveplates P/N # Diameter (mm )
WPS410 WPS210 10
WPS412 WPS212 12.7
WPS415 WPS215 15
WPS420 WPS220 20
WPS425 WPS225 25
WPS430 WPS230 30

 

Type 2: Zero Order Waveplate-Cemented
This type of zero order waveplate is constructed of a true zero order waveplate and a BK7 substrate. As the waveplate is very thin and easy to damage, the BK7 plate's function is to strengthen the waveplate. The modules cemented with BK7 substrates have the drawback of significantly reduced damage threshold (1~2J/cm2@1064nm,10ns,10Hz). The BK7 substrates might also be assembled together with the quartz plates by a glue-free method of diffusion bonding, which subsequently raises the damage threshold to 15J/cm2@1064nm,10ns,10Hz.

Features:

  • Standard Thickness:1.1±0.2mm
  • Cemented by NOA61 (Norland Optical Adhesive 61)
  • Wide Angle Acceptance
  • Better Temperature Bandwidth
  • Wide Wavelength Bandwidth
  • AR coating, R<0.2%

Standard wavelengths:

532nm, 632.8nm, 780nm, 808nm,980nm, 1064nm,1310nm, 1480nm, 1550nm

Specifications:

True Zero Order Waveplate-Cemented
Quarter Waveplates P/N # Half Waveplates P/N # Diameter (mm )
WPF410 WPF210 10
WPF412 WPF212 12.7
WPF415 WPF215 15
WPF420 WPF220 20
WPF425 WPF225 25
WPF430 WPF230 30

True zero order waveplate is an advanced and improved version of zero order waveplates with superior broadband performance. Although belonging to the zero-order category, unlike the net zero-order waveplates which generate the desired retardance by stacking two multiple-order waveplates and get the resulting retardation from the difference of phase shifts in the two plates, true zero-order waveplates feature extremely miniature thickness to provide exactly the required retardation (for example, a phase delay of precisely lambda/2 for a half waveplate). This feature bestows excellent retardation consistencies corresponding to wavelength change, ambient temperature change, and changes in incident angle on true zero-order waveplates. 

The most prevalent waveplates are half waveplates and quarter waveplates, half waveplates are frequently used to rotate vertical polarization to horizontal polarization while quarter waveplates are used for conversions between linear polarization and circular polarization Hangzhou Shalom EO offers multiple specifications of true zero order waveplates with half or quarter retardance:

Type 1: Quartz free-standing single plate

While the freestanding version may be relatively vulnerable and might cause inconvenience to the fabrication and handling process, the single plate has a high damage threshold(>1GW/cm2@1064nm,10ns,10Hz), therefore recommendable for high energy application. The standard wavelengths of quartz true zero order waveplates range from 532nm-1550nm, other wavelengths could be customized according to your requirements.

Hangzhou Shalom EO is capable of providing single plate true zero order waveplates of quartz, with a minimum thickness that produces π/2 phase delay for an 800nm light source and π/4 phase delay for a 1550nm light source.

Type2: Quartz single plate + BK7 substrate

The versions with BK7 substrates are either cemented using NOA61 (Norland Optical Adhesive 61, is an accredited optical grade adhesive sourced from Norland Products) or attached by optical bonding to strengthen the waveplates for easier operation. As for waveplates with BK7 substrates, the limit of our capability is down to 355nm (355nm excluded).

The modules cemented with BK7 substrates have the drawback of significantly reduced damage threshold (1~2J/cm2@1064nm,10ns,10Hz). The BK7 substrates might also be assembled with the quartz plates using a glue-free method of diffusion bonding, which subsequently raises the damage threshold to 15J/cm2@1064nm,10ns,10Hz.

Type 3: MgF2 true zero order waveplates

The true zero-order waveplates made of Magnesium Fluoride are recommendable for long-wavelength operations (e.g. Wavelengths above 3000nm.)


FAQs:

Here are some typical questions and answers about waveplates that might be helpful for buyers. The contents below are a summarized version, please check our Introduction to Waveplates and Retarders if you want to learn more.

How does a waveplate work?

Waveplates and Retarders are important optical components to manipulate and alter the polarization state of laser light. 

Waveplates are conventionally made by birefringent crystals such as Quartz and magnesium Fluoride. (There are also Retarders made from non-birefringent materials. The Fresnel Rhomb Retarder is an excellent example, which is usually made from BK7, UV Fused Silica, or ZnSe, realizing the phase delay by utilizing the Total Internal Reflection. The retardation generated by a Fresnel Rhomb depends virtually solely on the refractive index and the geometries of the prism.)

The anisotropy of these crystal materials results in the separation of one light beam into two light rays when hitting the interface. The two split light rays encounter different refractive indices: one called the Ordinary Ray, which is governed by the ordinary refractive index, and another called the Extraordinary ray, which is governed by the direction-sensitive extraordinary refractive index. The two rays always have their polarization direction perpendicular to each other.

Waveplates are purposefully sliced so that their optical surface is parallel to their optical axis. The ordinary ray and the extraordinary ray will experience different refractive indices and hence travel in different phase velocities. The axis in which the polarized electric vector travels with a greater velocity (Vfast=c/Nfast) is defined as the Fast axis. The one in which the electric vector travels with a lower velocity (Vslow=c/Nslow) is the Slow axis. The two axes are always orthogonal.

When a light beam is projected normally to the surface of a waveplate, different phase velocities of the two components will naturally introduce phase delay between the fast and the slow components, where the slow components will be several phases (or a fraction of phase) lagged behind the fast component. The magnitude of the phase delay is called Retardation. The retardation of a waveplate could be formulated as below:


ReTardation=2πL(Nslow-Nfast)/λ


Where L is the distance traveled by the incident light (the thickness of the waveplate), Nfast and Nslow are the refractive indices along the fast and slow axis respectively. 

The value of retardation might be written in various forms, for example, a “half-wave” retardation is equivalent to a retardation value of π radians or lambda/2.

From the equation above, it could be easily deduced that by deliberately designing the thickness of the waveplates, the desired retardation could be obtained. However, besides the thickness of a waveplate, other external factors will affect the retardation value, for example, the wavelengths of the incident light, the temperature of the operation environment, the angle of incidence, etc. The changes of retardation caused by external factors are often disturbing and detrimental and are what the manufacturers trying their best to avoid.

Finding the Axes?

Finding the fast axis of each waveplate is a critical step when using the waveplates. The mounted waveplates offered by Shalom EO are all designed with their fast axes indicated as a straight light on the mount. While the fast axis of the unmounted versions is all marked directly on the waveplates. However, if it happens that the axes are not indicated or the indications are blurred, there is a simple method to help you find the axes which apply for waveplates with all values of retardation. First, place a polarizer in front of the laser device, tilt the polarizer until the light is extinct, then interpose the waveplate between the laser device and the polarizer, rotate the waveplate so that the eventual light output is still extinct——and viola! you have found an axis successfully! 

Adjustments?

Additionally, It might happen that you find the waveplates you bought might not produce exactly the designed retardation. There are plenty of reasons: e.g. the waveplates are not designed for your wavelength of interest, or there are external factors such as temperature affecting the retardation. The small deviations could be modified by rotating the plane of polarization towards the fast or slow axis of the waveplate. Moving toward the fast axis reduces the retardation while moving towards the fast axis raises the retardation. Try both directions and keep checking the improvements using polarizers.

Buyer's guide to Waveplates and Retarders


waveplate selection guide


Understanding different types of Waveplates and Retarders are equally as important as figuring out their working principle, especially for buyers. Don’t worry, Shalom EO edited a brief guide for you, after reading that you might have a much clarified and profound understanding of waveplates.

Low Order Waveplates or Multiple Order Waveplates

Due to difficulties in the manufacturing stage, it could be hard to churn out large quantities of waveplates that are ultra-thin and which produce exactly the desired fractional retardance. The Low Order Waveplates, Or Multiple Order Waveplates are relatively thick and generate the desired retardation with several additional wavelengths of phase delay. Because light waves repeat themselves periodically, a low order half waveplate, which produces a phase delay of lambda/2 plus 3 additional lambdas could also function as a half waveplate. The word “Order” here refers to the number of additional wavelengths generated. In this text, a low order waveplate is better than multiple order waveplates because it produces less addition phase delay and its retardation is more precise. However, the surplus of retardation also implies that they are much more sensitive to changes in wavelengths, temperature, or the AOI than their zero order counterparts. 

Generally speaking, if you are looking for cheap buying-in-bulk waveplates for single wavelength applications, then Low Order Waveplates are just right for you. Shalom EO offers Low Order Waveplates of two material options (Quartz for Visible to Near-IR spectral or MgF2 for greater wavelengths up to 7000nm). 

Zero Order Waveplates

Zero Order Waveplates are essentially comprised of two multiple order or low order waveplates with their axes orthogonally aligned (aligning the fast axis of one waveplate to the slow axis of the another), the resulting retardation is the difference between two individual retardations produced by respectively by the two constituent waveplates. By combining two single waveplates together, Zero Order Waveplates effectively offset the impacts of external factors (wavelength change, ambient temperature) on the retardation, which means the retardation will be much more constant compared to the low order waveplates, making them competent for applications involving broadened wavelength. Nevertheless, they might still have rather susceptive responsiveness to variations of the angle of incidence. 

Shalom EO offers three types of Zero Order Waveplates: Air spaced Zero Order WaveplatesOptically Contacted Zero Order Waveplates and NOA61 Cemented Zero Order Waveplates. While the cemented zero order waveplates are the common alternative, for high energy operations, consider Air spaced zero order waveplates and optically contacted zero order waveplates, since the two types have relatively higher damage threshold than the cemented versions.

True Zero Order Waveplates

True Zero Order Waveplates are waveplates of single-plate structure and provide exactly the required retardation, therefore its thickness is usually only several micrometers. Although requiring relatively strict processing, the contracted thickness contributes to more superior retardation constancy against wavelength variations or climate changes than conventional Zero Order Waveplates. Shalom EO offers True Zero Order Waveplates made from Quartz (for 532-3000nm) or MgF2 (for long-wavelength applications from 3000-7000nm), the single plate versions are relatively fragile but are of high damage threshold, while the versions cemented with BK7 substrates are much easy to handle, but are of lower damage threshold.

Achromatic Waveplates

Achromatic Wavepltes are constructed by one MgF2 Waveplate and one Quartz Waveplates with their axes orthogonally aligned, of which the birefringent properties are complementary, achieving the required focal length while minimizing chromatic dispersion. Through this approach the intrinsic influence of wavelength shifts on the retardation is drastically reduced, making achromatic waveplates even more retardation-constant than zero order waveplates, thus eminent for various Broadband applications spanning wide spectral ranges (e.g. from 900-2000nm). Two application examples are Tunable laser sources, Femtosecond laser systems, etc.

Super Achromatic Waveplates

Super Achromatic Waveplates are virtually an upgraded version of achromatic waveplates. The operation principle of super achromatic waveplates is the same as that described of achromatic waveplates. Super achromatic waveplates are also compounded by two crystal materials (e.g. quartz and magnesium fluoride), but instead of two as in the case of achromatic waveplates, they consists of six single waveplates (three of Quartz, three of MgF2), the result is exceedingly flat retardation over even wider wavelength ranges. 

Fresnel Rhomb Retarders 

Fresnel Rhomb Retarders operates upon an entirely different principle other than exploiting the birefringence. A Fresnel Rhomb introduces phase difference between the components of light using total internal reflection. When light is projected on the interface, the electric field of the light wave splits into two perpendicular components, the s component, and the p component. The rhombs are strategically processed into the shape of a right parallelepiped, so that with the angle of incidence cautiously chosen, the p component will proceed lambda/8 relative to the s component at each total internal reflection underwent. When light emerges, after experiencing two total internal reflections, the p component will eventually be lambda/4 ahead of the s component, thus realizing the same function of a Quarter Waveplate. When constructing a Half Wave Fresnel Rhomb Retarder, two rhombs are cemented in tandem to avert reflections at the interface.

The Fresnel Rhombs are usually made from glass materials, which are non-birefringent, the typical three being BK7, UV Fused Silica, or ZnSe. Because the retardation introduced by the rhomb is related to the refractive index, which only varies slightly over a wide wavelength range, the Fresnel Rhomb Retarders have even broader wavelength capabilities than other broadband waveplates such as achromatic waveplates. 

Dual Wavelength Waveplates

Dual Wavelength Waveplates introduce two retardation values for two wavelengths through the fitting of the refractive index at different wavelengths. Dual Wavelength Waveplates are particularly useful when used in conjunction with other polarization-sensitive components to separate coaxial laser beams of different wavelengths or elevate and promote the conversion efficiency of Solid State SHG Lasers. Additionally, Dual Wavelength Waveplates could also be applied to THG Systems. Triple Wavelength Waveplates could also be customized by Shalom EO at your request.