click me!

Narrowband Filters for Enzyme Labeling Instruments

  • Mounted narrowband filters of hard coating
  • Substrate materials : Colored glass+BK7
  • Optical density: ≥OD4
  • Blocking wavelength range: 200-1200nm
  • Band Width:  10nm+/-1nm
Inquire for custom product  
Code Wavelength Diameter Aperture Bandwidth Unit Price Delivery Cart
411-013 405nm 6mm 4mm 10nm Inquire Inquire
411-014 405nm 8mm 6mm 10nm Inquire Inquire
411-015 405nm 10mm 6mm 10nm Inquire Inquire
411-016 405nm 10mm 7mm 10nm Inquire Inquire
411-017 405nm 12mm 8mm 10nm Inquire Inquire
411-018 405nm 15mm 12mm 10nm Inquire Inquire
412-007 450nm 6mm 4mm 10nm Inquire Inquire
412-008 450nm 8mm 6mm 10nm Inquire Inquire
412-009 450nm 10mm 6mm 10nm Inquire Inquire
412-010 450nm 10mm 7mm 10nm Inquire Inquire
412-011 450nm 12mm 8mm 10nm Inquire Inquire
412-012 450nm 15mm 12mm 10nm Inquire Inquire
411-019 492nm 6mm 4mm 10nm Inquire Inquire
411-020 492nm 8mm 6mm 10nm Inquire Inquire
411-021 492nm 10mm 6mm 10nm Inquire Inquire
411-022 492nm 10mm 7mm 10nm Inquire Inquire
411-023 492nm 12mm 8mm 10nm Inquire Inquire
411-024 492nm 15mm 12mm 10nm Inquire Inquire
412-019 540nm 6mm 4mm 10nm Inquire Inquire
412-020 540nm 8mm 6mm 10nm Inquire Inquire
412-021 540nm 10mm 6mm 10nm Inquire Inquire
412-022 540nm 10mm 7mm 10nm Inquire Inquire
412-023 540nm 12mm 8mm 10nm Inquire Inquire
412-024 540nm 15mm 12mm 10nm Inquire Inquire
412-025 570nm 6mm 4mm 10nm Inquire Inquire
412-026 570nm 8mm 6mm 10nm Inquire Inquire
412-027 570nm 10mm 6mm 10nm Inquire Inquire
412-028 570nm 10mm 7mm 10nm Inquire Inquire
412-029 570nm 12mm 8mm 10nm Inquire Inquire
412-030 570nm 15mm 12mm 10nm Inquire Inquire
412-031 590nm 6mm 4mm 10nm Inquire Inquire
412-032 590nm 8mm 6mm 10nm Inquire Inquire
412-033 590nm 10mm 6mm 10nm Inquire Inquire
412-034 590nm 10mm 7mm 10nm Inquire Inquire
412-035 590nm 12mm 8mm 10nm Inquire Inquire
412-036 590nm 15mm 12mm 10nm Inquire Inquire
411-037 630nm 6mm 4mm 10nm Inquire Inquire
411-038 630nm 8mm 6mm 10nm Inquire Inquire
411-039 630nm 10mm 6mm 10nm Inquire Inquire
411-040 630nm 10mm 7mm 10nm Inquire Inquire
411-041 630nm 12mm 8mm 10nm Inquire Inquire
411-042 630nm 15mm 12mm 10nm Inquire Inquire

Enzyme Labeling Instrument, also known as an Enzyme-linked immunosorbent assay (ELISA) reader, is a specialized instrument for enzyme-linked immunosorbent testing that utilizes colorimetric methods to analyze the content of antigens or antibodies. Whether automatic or semi-automatic, Testing often requires the final volume of the test solution to be below 250μ, necessitating a photometric colorimeter designed on purpose in the enzyme labeling instrument, this is where narrowband filters step in, functioning to obtain monochromatic light from the light source.  ELISA readers can be widely used in low ultraviolet regions for DNA and RNA quantification and purity analysis (A260/A280) and protein quantification (A280/BCA/Bradford/Lowry), enzyme activity, enzyme kinetics detection, cell proliferation and toxicity analysis, cell apoptosis detection, reporter gene detection, and G protein-coupled receptor receptors (GPCR).

Narrow bandpass filters offer high transmission within a narrow range of wavelengths centered around the center wavelength while blocking unwanted light.  Narrowband Filters for Enzyme Labeling Instruments utilize advanced optical engineering techniques to isolate specific wavelengths of light with remarkable accuracies, enhancing the performance of enzyme labeling instruments in detecting and quantifying enzymatic reactions. The working process of the narrow bandpass filters used in the ELISA reader is as follows: The light source emits light, which, after passing through the filters, is transformed into monochromatic light. This monochromatic light enters the plastic micropores containing the test specimen. A portion of the monochromatic light is absorbed by the specimen, while another part passes through the specimen, illuminating the photodetector. The photodetector converts different light intensity signals into corresponding electrical signals, which, after pre-amplification, logarithmic amplification, analog-to-digital conversion, and other signal processing, undergo final data processing and calculation. The results are then displayed by the monitor and printed by the printer. 

Shalom EO offers Narrowband Filters for Enzyme Labeling Instruments. Crafted using cutting-edge hard coating techniques, where filters are deposited onto substrates composed of colored glass bonded with BK7, ensuring robustness and durability in demanding laboratory environments. With a standard Optical Density of ≥OD4, these filters effectively block unwanted wavelengths, enabling precise and targeted analysis of enzymatic reactions. One of the critical features of our narrowband filters is their narrow bandwidth, the standard is 10nm+/-1nm. This narrow bandwidth allows for the sharp isolation of specific wavelengths relevant to the enzymatic reaction under investigation. Minimizing spectral overlap and background interference, these filters enhance the signal-to-noise ratio, thus improving the accuracies and reliabilities of enzymatic measurements. In addition to their standard configurations, narrowband filters can be customized to match the spectral characteristics of target analytes. 

Common Specifications:

Coating TypeHard CoatingFull Width-Half Max (FWHM)10.0+/-1nm
Minimum Transmission>50%Optical Density (OD)≧4.0
Block Wavelength Range200 ~1200nmSurface Quality80/50 S/D
Substrate MaterialsColored Glass + BK7
540nm CWL, 6mm Diameter, 10nm FWHM, OD 4 Narrow Bandpass Filter

540nm CWL, 6mm Diameter, 10nm FWHM, OD 4 Narrow Bandpass Filter

450nm CWL, 6mm Diameter, 10nm FWHM, OD 4 Narrow Bandpass Filter

450nm CWL, 6mm Diameter, 10nm FWHM, OD 4 Narrow Bandpass Filter

492nm CWL, 10mm Diameter, 10nm FWHM, OD 4 Narrow Bandpass Filter

492nm CWL, 10mm Diameter, 10nm FWHM, OD 4 Narrow Bandpass Filter